Test P: The LH Turn Signal Indicator Is Never/Always On
PINPOINT TEST P: THE LH TURN SIGNAL INDICATOR IS NEVER/ALWAYS ONP1:
P2-P5:
P5-P8:
Normal Operation
When the multifunction switch is in the LH TURN position, voltage is supplied to the instrument cluster from the generic electronic module (GEM) through circuit 49S-LG15 (BU/BK).
Possible Causes
- Circuit 49S-LG15 (BU/BK) open, short to ground or voltage
- GEM