Operation CHARM: Car repair manuals for everyone.

Test P: The LH Turn Signal Indicator Is Never/Always On

PINPOINT TEST P: THE LH TURN SIGNAL INDICATOR IS NEVER/ALWAYS ON


P1:






P2-P5:






P5-P8:






Normal Operation
When the multifunction switch is in the LH TURN position, voltage is supplied to the instrument cluster from the generic electronic module (GEM) through circuit 49S-LG15 (BU/BK).

Possible Causes
- Circuit 49S-LG15 (BU/BK) open, short to ground or voltage
- GEM
- Instrument cluster.