Test E: The Power Folding Mirrors Do Not Operate
PINPOINT TEST E: THE POWER FOLDING MIRRORS DO NOT OPERATENOTE: The power folding mirrors must be synchronized anytime the RH, LH or both power folding mirrors are folded or unfolded without using the power folding mirror control switch, or if a new power folding mirror has been installed. Refer to Exterior Mirror Motor Synchronization - Power Folding. Programming and Relearning
Normal Operation
When the exterior mirror control switch is set to the center position and pressed rearward to the FOLD/UNFOLD position, ground is supplied to the driver seat module (DSM) through circuit CPM22 (GY/BN). When the exterior mirrors are extended, and the DSM receives ground on circuit CPM22 (GY/BN), the DSM will ground circuits CPM39 (GN/VT) and CPM40 (WH/OG) and supply voltage to circuits CPM04 (VT/BN) and CPM07 (BN), and the LH and RH exterior mirrors will retract. When the exterior mirrors are retracted, and the DSM receives ground on circuit CPM22 (GY/BN), the DSM will ground circuit CPM39 (GN/VT) and CPM40 (WH/OG) and supply voltage to circuits CPM04 (VT/BN) and CPM07 (BN), and the LH and RH exterior mirrors will extend.
If the power folding mirrors are folded or unfolded continuously (6 to 10 cycles), the power lockout feature will disable the system for approximately 2 minutes to prevent damage to the power fold motors. After 2 minutes have elapsed, normal operation will resume.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Exterior mirror control switch
- Exterior mirror
- DSM