Test I: One Or More Stoplamps Are Inoperative
PINPOINT TEST I: ONE OR MORE STOPLAMPS ARE INOPERATIVENormal Operation
When the brake pedal is applied, the stoplamp switch routes voltage to the smart junction box (SJB) and the high mounted stoplamp through circuit CLS17 (YE/GY). When the SJB detects the brake pedal applied, the SJB provides voltage to the LH and RH rear stoplamps, and the LH and RH trailer tow turn relays through circuits CLS18 (GY/BN) and CLS19 (VT/OG), respectively. Ground for the LH and RH rear stoplamps is provided through circuits GD149 (BK/GY) and GD151 (BK/GN), respectively. Ground for the high mounted stoplamp is provided through circuit GD150 (BK/WH).
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- High mounted stoplamp
- Trailer tow turn relay
- SJB