Test C: No Power In Start

Pinpoint Test C: No Power in START

Normal Operation
The ignition switch is placed in the START position, fused battery voltage is supplied to the central junction box (CJB) along circuit 32 (RD/LB).

This pinpoint test is intended to diagnose the following:
^ Wiring, terminals or connectors
^ Ignition switch
^ CJB

C1-C2: