Operation CHARM: Car repair manuals for everyone.

Test M: The Blower Motor Is Inoperative - EMTC

PINPOINT TEST M: THE BLOWER MOTOR IS INOPERATIVE - EMTC

Normal Operation
Under normal operation, the blower motor relay coil receives ignition voltage through circuit CBP45 (YE). The coil receives ground from the HVAC module - electronic manual temperature control (EMTC) through circuit CH123 (VT/GN) if any function selector position but OFF is selected. Voltage is supplied to the relay switch contact. When the relay coil is energized, voltage is delivered to the blower motor through circuit CH402 (YE/GN). Ground for the blower motor is provided through circuit CH430 (VT/OG) from the blower resistor or the blower switch (HI). The blower resistor and blower switch is grounded through circuit GD115 (BK/GY).

This pinpoint test is intended to diagnose the following:
- Fuse(s)
- Wiring, terminals or connectors
- Blower motor
- Blower motor relay
- Blower motor switch
- Battery junction box (BJB)
- HVAC module - EMTC


M1-M2:






M2-M4:






M5-M6:






M6-M7:






M7-M8:






M8-M9:






M9-M10: