Operation CHARM: Car repair manuals for everyone.

System Specifications

Item Specification

Single Generator
Voltage 12 volts
Gas (3G) 70/115 amp (max) (R) 1,800-6,000 generator rpm, approximately 525-2,000 engine rpm
Diesel (SC1) (standard) 75/135 amp (max) (R) 1,800-6,000 generator rpm, approximately 525-2,000 engine rpm
Diesel (SC5) (optional) 95/200 amp (max) (R) 1,800-6,000 generator rpm, approximately 525-2,000 engine rpm

Generator
Load at 2,000 rpm (Standard) 75 amps
Load at 2,000 rpm (Optional) 95 amps
No Load at 2,000 rpm between 13.2 and 15.5 volts

Dual Generator
Voltage 12 volts
Lower (SC5) 95/200 amp (max) (R) 1,800-6,000 generator rpm, approximately 525-2,000 engine rpm
Upper (4G) 75/120 amp (max) (R) 1,800-6,000 generator rpm, approximately 525-2,000 engine rpm

Generator
Load at 2,000 rpm (Lower) 75 amps
Load at 2,000 rpm (Upper) 95 amps
No Load at 2,000 rpm between 13.0 and 15.5 volts