Test A: The Instrument Cluster (IC) Is Inoperative
PINPOINT TEST A: THE INSTRUMENT CLUSTER (IC) IS INOPERATIVENormal Operation
With the ignition switch in the START or RUN position, the instrument cluster (IC) receives voltage from the smart junction box (SJB) through circuit CBP29 (WH/VT). With the ignition switch in the OFF position, the instrument cluster (IC) receives its keep-alive memory (KAM) voltage from the SJB through circuit SBP26 (YE/RD). The instrument cluster (IC) grounding is through circuit GD134 (BK/VT). The instrument cluster (IC) sets DTC U2472 in continuous memory and on-demand if the RUN/START input, circuit CBP29 (WH/VT), is open or if the SJB fuse 29 (5A) has failed.
This pinpoint test is intended to diagnose the following:
- Fuse(s)
- Wiring, terminals or connectors
- Instrument cluster (IC)