Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the logical successor to CHARM, I recommend you try it!

Link: lemon-manuals.la

Compressor HVAC: Testing and Inspection

A/C COMPRESSOR - EXTERNAL LEAK TEST

1. Install the A/C Pressure Test Adapter on the port of the A/C compressor, using the existing manifold retaining bolt.
2. Connect the high and low pressure lines of a manifold gauge set or a refrigerant recovery/recycling station such as the R-134a A/C service center to the corresponding fittings on the A/C Pressure Test Adapter.
3. Attach the center hose of a manifold gauge set to a refrigerant container standing in an upright position.
4. Hand-rotate the compressor shaft 10 complete revolutions to distribute the oil inside the A/C compressor.
5. Open the low pressure gauge valve, the high pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.
6. Using the Refrigerant Leak Detector, check for leaks at the compressor shaft.
7. If a shaft seal leak is found, replace the compressor shaft seal. If an external leak is found, install a new A/C compressor.
8. When the leak test is complete, recover the refrigerant from the compressor.