Alternator: Service and Repair
GENERATORRemoval and Installation
1. Disconnect the battery.
2. Rotate the front end accessory drive belt tensioner clockwise and position the accessory drive belt aside.
3. Disconnect the 2 electrical connectors from the generator.
4. Position the protective cover aside, remove the nut and position the generator B+ terminal aside.
- To install, tighten to 8 Nm (71 lb-in).
5. Remove the 3 bolts and the generator.
- To install, tighten to 48 Nm (35 lb-ft).
6. To install, reverse the removal procedure.