Procedures
Transfer Case Draining and Filling1. Remove the drain plug and drain the fluid.
^ Clean and install the drain plug after fluid is drained.
^ Tighten to 24 Nm (18 lb-ft).
2. CAUTION: Incorrect fluid fill may result in transfer case failure.
NOTE: Clean the area around the fill plug.
Remove the fill plug and fill the transfer case.
^ The fluid must be just below the fill plug hole. Because the fluid can be reached with a finger does not mean the fluid is at the correct level. Make sure the fluid is level with the filler opening for the correct fluid level.
^ The total transfer case fill capacity is 1.2L (2.5 pt).
3. Install the fill plug.
^ Tighten to 24 Nm (18 lb-ft).