Compressor HVAC: Testing and Inspection




Climate Control System


Component Tests


A/C Compressor - External Leak Test

1. Install the A/C pressure test adapter on the rear head of the A/C compressor using the existing manifold retaining bolt.

2. Connect the high and low pressure lines of a manifold gauge set or a refrigerant recovery/recycling station to the corresponding fittings on the A/C pressure test adapter.

3. Attach the center hose of the manifold gauge set to a refrigerant container standing in an upright position.

4. Open the low pressure gauge valve, the high pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.

5. Using a refrigerant leak detector, check for leaks at the compressor shaft seal, the compressor front/rear head seal and the compressor rear head bolts.

6. If an external leak is found, install a new A/C compressor.

7. When the leak test is complete, recover the refrigerant from the compressor.