Air Cleaner Outlet Pipe
Air Cleaner Outlet Pipe
Removal and Installation
1. Disconnect the crankcase ventilation tube quick connect coupling from the Air Cleaner (ACL) outlet pipe.
2. Release the ACL outlet pipe retainer from the ACL housing.
3. Loosen the 2 clamps and remove the ACL outlet pipe.
- To install, tighten to 4 Nm (35 lb-in).
4. NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.
To install, reverse the removal procedure.