Variable Valve Timing Cover / Housing
Variable Camshaft Timing (VCT) HousingRH VCT housing
Position the RH VCT housing and install the 2 bolts.
- Tighten to 10 Nm (89 lb-in)
LH VCT housing
Position the LH VCT housing and install the 2 bolts.
- Tighten to 10 Nm (89 lb-in)