Pinpoint Test S: An Individual Fog Lamp Is Inoperative
Fog Lamps
Pinpoint Test S: An Individual Fog Lamp Is Inoperative
Refer to Wiring Diagram Set 86, Fog Lamps for schematic and connector information. Diagrams By Number
Normal Operation
When the fog lamp relay is energized, voltage is routed through circuit CLF12 (BN/YE) to the fog lamps. Ground is provided to the LH fog lamp through circuit GD120 (BK/GN) and the RH fog lamp through circuit GD123 (BK/GY).
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
PINPOINT TEST S: AN INDIVIDUAL FOG LAMP IS INOPERATIVE
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
NOTE: Make sure the bulb is OK before carrying out diagnostics.