Pinpoint Tests
Fuel System
Pinpoint Test A: Slow to Fill
Normal Operation
Under normal operation, fuel should flow at a steady rate through the fuel tank filler pipe into the fuel tank. As fuel enters the fuel tank air is vented through the filler pipe or the On-Board Refueling Vapor Recovery (ORVR) system.
This pinpoint test is intended to diagnose the following:
- Fuel tank filler pipe vent tube, if equipped
- Fuel tank filler pipe
- Evaporative Emission (EVAP) system
- Fuel tank inlet check valve (part of the fuel tank)
- Fuel level vent valve, if equipped (part of the Fuel Pump (FP) module)
PINPOINT TEST A: SLOW TO FILL