Thermostatic Expansion Valve - Auxiliary Climate Control
Thermostatic Expansion Valve
Removal and Installation
1. Remove the auxiliary climate control housing. For additional information, refer to Auxiliary Climate Control Housing Auxiliary Climate Control Housing.
2. Remove the auxiliary Thermostatic Expansion Valve (TXV) fitting bolt and disconnect the fitting.
- Discard the gasket seals.
- To install, tighten to 15 Nm (133 lb-in).
3. Remove the 2 auxiliary TXV bolts and the TXV.
- Discard the gasket seals.
- To install, tighten to 8 Nm (71 lb-in).
4. Remove the auxiliary TXV insulator pad.
5. To install, reverse the removal procedure.