Pinpoint Tests AD: The Passive Anti-Theft System (PATS) Indicator Is Never/Always On
Instrumentation, Message Center and Warning Chimes
Pinpoint Tests
Pinpoint Test AD: The Passive Anti-Theft System (PATS) Indicator Is Never/Always On
Normal Operation
The Passive Anti-Theft System (PATS) uses a visual anti-theft indicator located in the Instrument Cluster (IC). This indicator proves out for 3 seconds when the key is turned to the ON or START position under normal operation. If there is a PATS concern, this anti-theft indicator either flashes rapidly or glows steadily (for more than 3 seconds) when the key is turned to the ON or the START position. PATS also flashes the anti-theft indicator every 2 seconds at key off to act as a visual theft deterrent. The anti-theft indicator is controlled by the IC.
This pinpoint test is intended to diagnose the following:
- PATS concern
- IC
PINPOINT TEST AD: PATS INDICATOR IS NEVER/ALWAYS ON
-------------------------------------------------
AD1 CARRY OUT THE IC PATS INDICATOR ACTIVE COMMAND USING THE SCAN TOOL
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: IC DataLogger.
- Select the IC PATS indicator (THEFT_LMP) active command. Command the PATS indicator on and off. Observe the PATS indicator.
- Does the PATS indicator illuminate when commanded on and turn off when commanded off?
Yes
GO to AD2.
No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.
-------------------------------------------------
AD2 RETRIEVE THE RECORDED DTCs FROM THE IC SELF-TEST
- Check for recorded continuous memory IC DTCs.
- Are any PATS related DTCs recorded?
Yes
REFER to Antitheft and Alarm Systems.
No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.
-------------------------------------------------