Principles of Operation
Headlamps
Principles of Operation
Exterior Lighting
The Steering Column Control Module (SCCM) monitors the headlamp switch position by sending voltage signals on multiple circuits to the headlamp switch. There is one circuit for each headlamp switch position. At any given time, one of the signal circuits is switched to ground. The SCCM sends a message to the Body Control Module (BCM) over the High Speed Controller Area Network (HS-CAN), indicating the headlamp switch status.
When the BCM receives input requesting the headlamps on, it supplies voltage to the headlamp bulbs.
If the SCCM does not detect any active inputs from the headlamp switch for 5 seconds, or if the SCCM detects multiple headlamp switch input circuits are active, the SCCM sends a message to the BCM to indicate the fault. The BCM then turns the parking lamps and headlamps on and keeps them on until the battery saver times out.
Refer to Exterior Lighting Exterior Lighting in the Description and Operation for information regarding the battery saver function.
If either situation occurs, the SCCM and the BCM cannot be ruled immediately as being at fault. This is normal behavior for the SCCM and the BCM when a fault has been detected with the inputs from the headlamp switch.
High Beam and Flash-to-Pass
The SCCM monitors the multifunction switch for a flash-to-pass and high beam request. When the multifunction switch is in the FLASH-TO-PASS or HIGH BEAM position, the SCCM sends a message to the BCM to indicate the request.
When the BCM receives a request for high beams (the low beams must be on), the BCM supplies voltage to the high beams.
When the flash-to-pass is requested, the high beams are illuminated as long as the multifunction switch is held in the FLASH-TO-PASS position (regardless if the low beams are on or off).
Field-Effect Transistor (FET) Protection
A Field-Effect Transistor (FET) is a type of transistor that, when used with module software, monitors and controls current flow on module outputs. The FET protection strategy prevents module damage in the event of excessive current flow.
The BCM utilizes a FET protective circuit strategy for many of its outputs (such as a headlamp output circuit). Output loads (current level) are monitored for excessive current (typically short circuits) and are shut down when a fault event is detected. A short circuit DTC is stored at the fault event and a cumulative counter is started.
When the demand for the output is no longer present, the module resets the FET protection, allowing the circuit to function. If the circuit is still shorted the next time the driver requests a circuit to activate that has been shut down by a previous short (FET protection), the FET protection shuts off the circuit again and the cumulative counter advances.
When the excessive circuit load occurs often enough, the module shuts down the output until a repair procedure is carried out. Each FET protected circuit has 3 predefined levels of short circuit tolerance based on the harmful effect of each circuit fault on the FET and the ability of the FET to withstand it. A module lifetime level of fault events is established based upon the durability of the FET. If the total tolerance level is determined to be 600 fault events, the 3 predefined levels would be 200, 400 and 600 fault events.
When a tolerance level is reached, the short circuit DTC that was stored on the first failure cannot be cleared by the clear the continuous DTCs command. The module does not allow this code to be cleared or the circuit restored to normal operation until a successful self-test proves that the fault has been repaired. After the self-test has successfully completed (no on-demand DTCs present), DTC U1000:00 and the associated DTC (the DTC related to the shorted circuit) automatically clears and the circuit function returns. The module never resets the fault event counter to zero and continues to advance the fault event counter as short circuit fault events occur.
If the number of short circuit fault events reach the third level, then DTCs U1000:00 and U3000:49 set along with the associated short circuit DTC. DTC U3000:49 cannot be cleared and the module must be replaced after the repair.
The BCM FET protected output circuits for the headlamp system are both low and high beam output circuits.