Pinpoint Test A: The Alarm System Does Not Activate From An Unauthorized Entry At The Hood
Anti-Theft
Pinpoint Tests
Pinpoint Test A: The Alarm System Does Not Activate From An Unauthorized Entry At The Hood
Refer to Wiring Diagram Set 117, Remote Keyless Entry and Alarm for schematic and connector information. Diagrams By Number
Normal Operation
When the alarm system is armed, the Body Control Module (BCM) monitors the hood switch. If the hood is opened while the alarm is armed, the hood switch removes ground from the signal circuit. This signals the BCM that an unauthorized intrusion to the engine compartment has occurred and the BCM activates the alarm.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Hood switch
- BCM
PINPOINT TEST A: THE ALARM SYSTEM DOES NOT ACTIVATE FROM AN UNAUTHORIZED ENTRY AT THE HOOD
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
-------------------------------------------------
A1 RETRIEVE THE RECORDED DTCs IN THE BCM
NOTE: DTC B1305:01 sets if the hood is open. Make sure the hood is closed prior to running the self-test.
- Retrieve the recorded DTCs from the Body Control Module (BCM) self-test.
- Is DTC B1305:01 present?
Yes
GO to Pinpoint Test B. Pinpoint Test B: DTC B1305:01
No
GO to A2.
-------------------------------------------------
A2 CHECK THE HOOD SWITCH (HOOD_SW) PID
- Enter the following diagnostic mode on the scan tool: BCM DataLogger.
- Disconnect: Hood Switch C127.
- Monitor the BCM PID HOOD_SW while disconnecting the hood switch.
- Does the BCM PID read AJAR when the switch is disconnected?
Yes
INSTALL a new hood switch. TEST the system for normal operation.
No
GO to A3.
-------------------------------------------------
A3 CHECK THE HOOD SWITCH INPUT CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: BCM C2280F.
- Measure the resistance between the hood switch C127-1, circuit CPL25 (BU/OG), harness side and ground.
- Is the resistance greater than 10,000 ohms?
Yes
GO to A4.
No
REPAIR circuit CPL25 (BU/OG) for a short to ground. TEST the system for normal operation.
-------------------------------------------------
A4 CHECK FOR CORRECT BCM OPERATION
- Disconnect all the BCM connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the BCM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
Yes
INSTALL a new BCM. REFER to Multifunction Electronic Modules Service and Repair. TEST the system for normal operation.
No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
-------------------------------------------------