Refer to Wiring Diagram Set 100, Power Windows for schematic and connector information. Diagrams By Number

Normal Operation

The RH rear window control switch receives voltage from the LH front window control switch when the lock-out switch is in the UNLOCK position. Ground is also provided to the RH rear window control switch from the LH front window control switch. The RH rear window control switch transfers voltage and ground to the power window motor. Window direction is controlled by reversing polarity of the voltage and ground circuits being supplied to the power window motor.

When operating the RH rear window from the LH front window control switch, voltage and ground is sent from the LH front window control switch through the normally closed contacts within the RH rear window control switch. Window direction is controlled by reversing polarity of the voltage and ground circuits being supplied to the power window motor.

This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Window control switch
- Power window motor

PINPOINT TEST F: A SINGLE POWER WINDOW IS INOPERATIVE - RH REAR

NOTICE: Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

-------------------------------------------------
F1 CHECK THE VOLTAGE TO THE RH REAR WINDOW CONTROL SWITCH

- Disconnect: RH Rear Window Control Switch C801.
- Ignition ON.

- NOTE: Set the LH front window lock-out switch to the UNLOCK position.

- Measure the voltage between RH rear window control switch C801-2, circuit CPW14 (VT/WH), harness side and ground.




- Is the voltage greater than 10 volts?

Yes
GO to F3.

No
GO to F2.

-------------------------------------------------
F2 CHECK THE WINDOW CONTROL SWITCH POWER CIRCUIT FOR AN OPEN

- Ignition OFF.
- Disconnect: LH Front Window Control Switch C535B.
- Measure the resistance between RH rear window control switch C801-2, circuit CPW14 (VT/WH), harness side and LH front window control switch C535B-4, circuit CPW14 (VT/WH), harness side.




- Is the resistance less than 5 ohms?

Yes
INSTALL a new LH front window control switch. REFER to Window Control Switch - Front Window Control Switch - Front. TEST the system for normal operation.

No
REPAIR the circuit. TEST the system for normal operation.

-------------------------------------------------
F3 CHECK THE GROUNDS TO THE LH REAR WINDOW CONTROL SWITCH

- Ignition OFF.
- Measure the resistance between RH rear window control switch C801-1, circuit CPW18 (GY/VT), harness side and ground; and between RH rear window control switch C801-3, circuit CPW17 (BN/GN), harness side and ground.




- Are the resistances less than 5 ohms?

Yes
GO to F5.

No
GO to F4.

-------------------------------------------------
F4 CHECK CIRCUITS CPW17 (BN/GN) AND CPW18 (GY/VT) FOR AN OPEN

- Disconnect: LH Front Window Control Switch C535B.
- Measure the resistance between RH rear window control switch C801, harness side and LH front window control switch C535B, harness side using the following chart:








- Are the resistances less than 5 ohms?

Yes
INSTALL a new LH front window control switch. REFER to Window Control Switch - Front Window Control Switch - Front. TEST the system for normal operation.

No
REPAIR the circuit(s). TEST the system for normal operation.

-------------------------------------------------
F5 CHECK THE RH REAR WINDOW OPERATION

- Ignition ON.

- NOTE: Set the LH front window lock-out switch to the UNLOCK position.

- Connect a fused jumper wire between RH rear window control switch C801-2, circuit CPW14 (VT/WH), harness side and C801-6, circuit CPW23 (GY), harness side; and a second fused jumper wire between RH rear window control switch C801-4, circuit CPW24 (WH/VT), harness side and C801-1, circuit CPW18 (GY/VT), harness side. The RH rear window should operate in the downward direction.




- Connect a fused jumper wire between RH rear window control switch C801-2, circuit CPW14 (VT/WH), harness side and C801-4, circuit CPW24 (WH/VT), harness side; and a second fused jumper wire between RH rear window control switch C801-6, circuit CPW23 (GY), harness side and C801-3, circuit CPW17 (BN/GN), harness side. The RH rear window should operate in the upward direction.




- Does the LH rear window operate correctly?

Yes
If the RH rear window did not operate with the RH rear window control switch, INSTALL a new RH rear window control switch. REFER to Window Control Switch - Rear Window Control Switch - Rear. TEST the system for normal operation.

If the RH rear window did operate with the RH rear window control switch, but not with the LH front window control switch, INSTALL a new LH front window control switch. REFER to Window Control Switch - Front Window Control Switch - Front. TEST the system for normal operation.

No
GO to F6.

-------------------------------------------------
F6 CHECK THE POWER WINDOW MOTOR CIRCUITS FOR AN OPEN

- Ignition OFF.
- Disconnect: RH Rear Power Window Motor C828 (SuperCab) or C803 (SuperCrew).
- For SuperCab, measure the resistance between RH rear window control switch C801, harness side and RH rear power window motor C828, harness side using the following chart:








- For SuperCrew, measure the resistance between RH rear window control switch C801, harness side and RH rear power window motor C803, harness side using the following chart:








- Are the resistances less than 5 ohms?

Yes
INSTALL a new RH rear power window motor. REFER to Window Regulator Motor Window Regulator Motor. TEST the system for normal operation.

No
REPAIR the circuit(s). TEST the system for normal operation.

-------------------------------------------------