Operation CHARM: Car repair manuals for everyone.

Condenser to Evaporator Line




Condenser to Evaporator Line













Removal and Installation

1. Recover the refrigerant. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.

2. Disconnect the evaporator inlet fitting.
- Discard the O-ring seals.

3. Remove the condenser outlet fitting nut and disconnect the fitting.
- Discard the O-ring seal.

- To install, tighten to 8 Nm (71 lb-in).

4. To install, reverse the removal procedure.
- Install new O-ring seals.

- Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to Climate Control System - General Information and Diagnostics Refrigerant Oil Adding.

5. Evacuate, leak test and charge the refrigerant system. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.