Auxiliary Input / Output Jack: Service and Repair
Universal Serial Bus (USB) Cable and Port
Removal and Installation
1. Remove the instrument cluster finish panel.
2. Disconnect the Universal Serial Bus (USB) cable and port-to-bezel connector.
3. Remove the USB (Universal Serial Bus) cable and port.
- Disconnect the USB (Universal Serial Bus) cable from the Accessory Protocol Interface Module (APIM).
- Cut the USB (Universal Serial Bus) port and cable ends and secure them to prevent Noise, Vibration and Harshness (NVH) concerns.
4. To install, reverse the removal procedure.
- Secuere the new USB (Universal Serial Bus) port and cable as necessary, to prevent NVH (Noise, Vibration and Harshness) concerns.