Automatic Transaxle/Transmission - TorqShift(R)
General Specifications
Assembly Weight
Clutch, Solenoid, Application Chart (A)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LP = Low Pressure
HA = High Current
LA = Low Current
A = Applied
(I) = Inversely Proportional
a PCM Calibration Controlled
b Cold Strategy
Clutch, Solenoid, Application Chart (B)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LP = Low Pressure
HA = High Current
LA = Low Current
A = Applied
(D) = Directly Proportional
a Cold Strategy
Clutch, Solenoid, Application Chart (C)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LP = Low Pressure
HA = High Current
LA = Low Current
A = Applied
(D) = Directly Proportional
(I) = Inversely Proportional
a PCM Calibration Controlled
b 207 kPa (30 psi) until speed reaches 5 km/h (3 mph)
c Clutch Applied Through Manual Valve Position
d Cold Strategy
Clutch, Solenoid, Application Chart (D)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
O/R = Overrunning
LP = Low Pressure
LA = Low Current
X = Holding
(D) = Directly Proportional
a PCM Calibration Controlled
b Cold Strategy
Clutch, Solenoid, Application Chart (E)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LP = Low Pressure
HA = High Current
LA = Low Current
A = Applied
(I) = Inversely Proportional
a PCM Calibration Controlled
b Cold Strategy
Clutch, Solenoid, Application Chart (F)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LP = Low Pressure
HA = High Current
LA = Low Current
A = Applied
(D) = Directly Proportional
(I) = Inversely Proportional
a PCM Calibration Controlled
b 207 kPa (30 psi) until speed reaches 5 km/h (3 mph)
c Clutch Applied Through Manual Valve Position
d Cold Strategy
Clutch, Solenoid, Application Chart (G)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LA = Low Current
LP = Low Pressure
HA = High Current
A = Applied
(I) = Inversely Proportional
a PCM Calibration Controlled
Clutch, Solenoid, Application Chart (H)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LP = Low Pressure
HA = High Current
LA = Low Current
A = Applied
(I) = Inversely Proportional
Clutch, Solenoid, Application Chart (I)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
HP = High Pressure
LP = Low Pressure
HA = High Current
LA = Low Current
A = Applied
(D) = Directly Proportional
(I) = Inversely Proportional
Clutch, Solenoid, Application Chart (J)
NOTE: The Power Take-Off (PTO) may operate in any gear including PARK and NEUTRAL and does not require the overdrive One-Way Clutch (OWC). The torque converter may engage in PARK and NEUTRAL with PTO (Power Take-Off) engaged.
O/R = Overrunning
X = Holding
(D) = Directly Proportional
a PCM Calibration Controlled
Pressure Chart A
NOTE: Actual and commanded pressures vary based on calibration and transmission adaptive strategies. All pressures listed are approximate.
a Commanded pressure as viewed on diagnostic equipment.
Pressure Chart B
NOTE: Actual and commanded pressures vary based on calibration and transmission adaptive strategies. All pressures listed are approximate.
a Commanded pressure as viewed on diagnostic equipment.
Pressure Chart C
NOTE: Actual and commanded pressures vary based on calibration and transmission adaptive strategies. All pressures listed are approximate.
a Commanded pressure as viewed on diagnostic equipment.
b SSPCD commanded pressure as viewed on diagnostic equipment will be zero. The manual valve controls pressure to the direct clutch in the R detent position.
Pressure Chart D
NOTE: Actual and commanded pressures vary based on calibration and transmission adaptive strategies. All pressures listed are approximate.
a Commanded pressure as viewed on diagnostic equipment.
Shift Speeds
NOTE: All shift speeds are nominal and vary with calibration, model, axle ratio and tire size.
a Indicates cold strategy
Stall Speed Chart
Forward Clutch Pack
Direct Clutch Pack
Intermediate Clutch Pack
Coast Clutch Pack
Reverse Clutch Pack
Overdrive Clutch Pack
Torque Specifications
a Refer to the procedure in Automatic Transmission/Transaxle.