Pinpoint Test G: An Individual Courtesy Lamp Is Inoperative
Interior Lighting
Pinpoint Test G: An Individual Courtesy Lamp Is Inoperative
Refer to Wiring Diagrams Set 89, Interior Lamps for schematic and connector information. Electrical Diagrams
Normal Operation
Based on the input status, the Smart Junction Box (SJB) supplies voltage to the courtesy lamps.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Interior lamp
PINPOINT TEST G : AN INDIVIDUAL COURTESY LAMP IS INOPERATIVE
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
G1 CHECK THE INTERIOR LAMP
- Ignition OFF.
- Disconnect: Suspect Interior Lamp.
- Open the driver door.
- Measure the voltage between the suspect interior lamp connector, harness side as follows:
Location Connector-Pin/ Circuit Connector-Pin/ Circuit Front interior lamp C929-2 VLN33 (GY/VT) C929-1 GD133 (BK) Second row interior lamp C961-1 VLN33 (GY/VT) C961-2 GD133 (BK) Third row interior lamp C963-1 VLN33 (GY/VT) C963-2 GD133 (BK) Second row LH lamp (grab handle) C9009-1 VLN33 (GY/VT) C9009-2 GD133 (BK) Second row RH lamp (grab handle) C9010-1 VLN33 (GY/VT) C9010-2 GD133 (BK)
Is the voltage greater than 10 volts?
Yes
For the LH or RH second row lamps, INSTALL a new interior lamp for the lamp in question. TEST the system for normal operation.
For all other interior lamps, INSTALL a new interior lamp for the lamp in question. REFER to Interior Lamp . TEST the system for normal operation.
No
GO to G2.
G2 CHECK FOR VOLTAGE TO THE INTERIOR LAMP
- Measure the voltage between the suspect interior lamp, harness side and ground as follows:
Location Connector-Pin Circuit Front interior lamp C929-2 VLN33 (GY/VT) Second row interior lamp C961-1 VLN33 (GY/VT) Third row interior lamp C963-1 VLN33 (GY/VT) Second row LH lamp (grab handle) C9009-1 VLN33 (GY/VT) Second row RH lamp (grab handle) C9010-1 VLN33 (GY/VT)
Is the voltage greater than 10 volts?
Yes
REPAIR circuit GD133 (BK) for an open. TEST the system for normal operation.
No
REPAIR circuit VLN33 (GY/VT) for an open. TEST the system for normal operation.