Troubleshooting Hints - Power Driver's Seat
1. Check to see that the PWR ACCY Circuit Breaker is resetting. Replace if necessary.2. Check that G200 is clean and tight.
3. Check that there are not any obstructions under the seat or in the carriages which may affect Power Seat Operation.
^ Check for a broken (or partially broken) wire inside of the insulation which could cause system malfunction "GOOD" in a continuity /voltage check with a system disconnected. These circuits may be intermittent or resistive when loaded, and if possible, should be checked by monitoring for a voltage drop with the system operational (under load).
^ Check for proper insulation of the aftermarket electronic equipment which may affect the integrity of other system (Refer "Troubleshooting Procedures"). Diagnostic Aids