Operation CHARM: Car repair manuals for everyone.

Detecting Electrical Intermittents


PROCEDURE
Use the following procedure to detect intermittent terminal contact or a broken wire with an intermittent connection inside the insulation.

The J 39200 Digital Multimeter has the ability to monitor current, resistance, or voltage while recording the minimum (MIN) and maximum (MAX) values measured. The meter can also be set to display the average (AVG) value measured.

When diagnosing circuits that have voltage applied, use the voltage setting to monitor a connector (or length of a circuit) which is suspected of having an intermittent connection but is currently operating normally.
1. Connect the J 39200 Digital Multimeter to both sides of a suspect connector (still connected) or from one end of a suspect circuit to the other. This will continuously monitor the terminal contacts or length of wire being checked. Refer Meter Connections for examples of the various methods for connecting the meter to the circuit. Meter Connections
2. Set the meter for voltage. Since the "MIN MAX" mode does not use auto ranging, manually select the voltage range necessary before proceeding.
3. Press the "MIN MAX" button. The meter should read "100 ms RECORD" (100 millisecond record) and emit a 1/4 second beep. The meter is now ready to record and will generate an audible tone for any change in voltage. At this point, you may wish to press the "PEAK MIN MAX" button, which will record any voltage variations that occur for at least 1 millisecond.
4. Try to simulate the condition that is potentially causing an intermittent connection, either by wiggling connections or wiring, test driving or performing other operations. If an open or resistance is created, a voltage will be present and the meter will emit a tone for as long as the open or resistance exists. Any change in voltage will cause the meter to emit a tone for no less than 1/4 second. (Listening for a tone while manipulating wiring is very helpful for narrowing down an intermittent connection.)

Use the MIN and MAX values when the meter is out of sight or sound range, in noisy areas or for test driving when it may not be possible to monitor the meter.

To check the MIN and MAX recorded voltages press "MIN MAX" once for MAX and twice for MIN. A variation between MIN and MAX recorded voltages (unless nearly 0 volts) suggests an intermittent open or that resistance exists and should be repaired as necessary.

IMPORTANT: The "100 ms RECORD" (100 millisecond record) mode is NOT the amount of time allowed to perform a specific procedure. It is the amount of time used to record each snapshot of information used for calculating "AVG" when in the "MIN MAX" mode.