With A/C
Evaporator and Blower Assembly Component View:
Evaporator and Blower Case Replacement:
Control Assembly Replacement:
REMOVE OR DISCONNECT
1. Charge air cooler.
2. Negative battery cable.
3. Refrigerant from the system.
4. Electrical connections.
5. Refrigerant outlet line (109) from the accumulator (4).
- Cap or plug open lines.
6. Case flange screws (139) and nuts (147).
7. Blower case (140) with the accumulator (4).
IMPORTANT: Drain refrigerant oil from the accumulator into a clean container. Measure and add new oil.
INSTALL OR CONNECT
1. Blower case (140) with the accumulator (4).
IMPORTANT: Add 0.057 kg (2 oz.) of clean refrigerant oil PLUS an amount equal to that drained.
2. Refrigerant inlet line (108) to the accumulator (4).
IMPORTANT: Add 0.057 kg (2 oz.) of clean refrigerant oil PLUS an amount equal to that drained.
- Use clean 525 viscosity refrigerant oil on the seal.
- Tighten connector to 24 Nm (18 ft. lbs.).
3. Electrical connection (154).
4. Negative battery cable.
5. Charge air cooler.
6. Refrigerant to the system.
- Evacuate, charge and leak test.