Blower Motor and Fan Replacement (RPO C42)
REMOVAL PROCEDURE1. Disconnect the VCM or the PCM.
2. Remove the coolant reservoir.
3. Remove the rear coolant recovery reservoir mounting stud.
4. Disconnect the cooling tube from the blower motor.
5. Disconnect the electrical connector (1).
6. Remove the 5 blower motor and tan assembly mounting bolts (2).
7. Remove the blower motor and fan assembly.
INSTALLATION PROCEDURE
1. Install the blower motor and fan assembly.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the 5 blower motor and fan assembly mounting bolts (2).
Tighten
Tighten the bolts to 4.5 N.m (40 lb in).
3. Connect the electrical connector (1).
4. Connect the cooling tube to the blower motor.
5. Install the rear coolant recovery reservoir mounting stud.
6. Install the coolant reservoir.
7. Install the VCM or the PCM.
8. Perform the heater function test. Refer to Function Test.
For a description of the RPO Code(s) shown in this article/image, refer to the RPO Code List found at Vehicle/Application ID.
Application and ID