Motor Housing Disassembly/Reassembly
Motor Housing Disassembly/Reassembly1. Remove the IMA motor housing.
2. Remove the terminal cover (A), busbars (B), shield male connector (C).
3. Install the parts in the reverse order of removal.
NOTE: When installing the terminal, make sure the direction is secure.
4. Install the IMA motor housing.
5. Do the MOTOR ROTOR POSITION CALIBRATION.