Cargo Area Light Test/Replacement1. Turn the light switch OFF.
2. Carefully pry off the lens (A) with a small screwdriver.
3. Remove the two mounting screws.
4. Disconnect the 3P connector (B) from the housing (C).
5. Check for continuity between the terminals
- There should be continuity between the No. 1 and No. 2 terminals with the switch in the MIDDLE position.
- There should be continuity between the No. 2 and No. 3 (Body ground) terminals with the switch in the ON position
6. Install in the reverse order of removal.