Insufficient Heating (Without Climate Control)
Insufficient heating
Diagnostic Procedure:
1. Check the coolant level Testing and Inspection
2. Check the radiator cap Testing and Inspection
3. Check the operation of the air mix control motor and door Air Mix Control Motor Replacement (Without Climate Control)
4. Check the coolant temperature
5. Check the blower motor unit for obstructions
6. Check for air leaks around the ducts and vents
7. Check the inlet hose temperature
8. If it is COLD, check for restrictions in the hose, a damaged or leaking thermostat, and a damaged or leaking water pump.
9. If it is HOT, check for restrictions in the heater core. Back flush the heater core using standard commercially available equipment, or replace the heater core.
Also check for:
- Damaged cylinder head gasket