Operation CHARM: Car repair manuals for everyone.

Repair Procedures





Replacement

1. Discharge refrigerant from refrigeration system.
2. Replace faulty tube or hose.

CAUTION:
Cap the open fittings immediately to keep moisture or dirt out of the system.

3. Tighten joint of bolt or nut to specified torque.

CAUTION:
Connections should not be tighter than the specified torque.





4. Evacuate air in refrigeration system and charge system with refrigerant.

600 ± 25(g) (21.164 ± 0.88 [oz])

5. Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant.
6. Inspect A/C operation.