Wiper Switch: Testing and Inspection
Check the switch for continuity between the terminals.
If continuity is not as specified replace the switch.
1.
Time specification
-
T1 : Max.
0.7 sec.
-
T2 :
1.5 ± 0.7 sec. (at VR=0 K Ohms) -
T2 :
10.5 ± 3 sec. (at VR=50 K Ohms) 2.
Variable resistance (VR) :
0 Ohms - 50 K Ohms