Power Window Relay: Testing and Inspection
Relay 1.
Check the continuity between the terminals "3" and "5" with an ohmmeter.
2.
Apply DC
12V to the terminal "3" and ground the terminal "5".
3.
Check for continuity between the terminals "1" and "2".