Accumulator HVAC: Testing and Inspection
It will be necessary to replace the accumulator for the following reasons.
1.
The accumulator is restricted, plugged or perforated.
2.
The system has been left open for more than
24 hours. (system completely discharged)
3.
There is evidence of moisture in the system.
4.
A component such as a condenser,
evaporator core, refrigerant line or compressor that has seized is replace.