Knock Sensor: Testing and Inspection
SENSOR INSPECTION 1.
Disconnect the
knock sensor connector and measure resistance between terminals 1 and 2.
Standard value: about
5 MOhms 2.
If the resistance is continuous, replace the
knock sensor.
Tightening torque
Knock sensor:
16 - 25 Nm (160 - 240 kg.cm, 11.8 - 18.4 lb.ft) 3.
Measure the capacitance between terminals 1 and 2.
Standard value: