Positive Crankcase Ventilation Valve: Service and Repair
POSITIVE CRANKCASE VENTILATION (PCV) VALVEREMOVAL
1. Remove the valve pad (A) and disconnect the vacuum hose (B).
2. Remove the PCV Valve.
INSPECTION
1. Remove the PCV valve.
2. Insert a thin stick(A) into the PCV valve(B) from the threaded side to check that the plunger moves.
3. If the plunger does not move, the PCV valve is clogged. Clean it or replace.
INSTALLATION
Install the PCV valve and tighten to the specified torque.
PCV Valve installation : 7.8 - 11.8 N.m (0.8 - 1.2 kgf.m, 5.8 - 8.7lbf.ft)