With Manufacturer's Scan Tool
SELF-DIAGNOSIS RESULT CHECK With CONSULT-II
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which performs CAN communication.
3. Turn ignition switch ON.
4. Select "AIR PRESSURE MONITOR" on "SELECT SYSTEM" screen.
5. Select "SELF-DIAG RESULTS" on "SELECT DIAG MODE" screen.
6. Check display contents in self-diagnostic results.
7. Turn ignition switch OFF to prepare for erasing the memory.
8. Start engine and touch "START (NISSAN BASED VHCL)", "AIR PRESSURE MONITOR", "SELF-DIAG RESULTS", "ERASE MEMORY" in order on CONSULT-II screen to erase the error memory.
CAUTION: If the error memory is not erased, re-conduct the operation again.
NOTE: Before performing the self-diagnosis, be sure to register the ID. Or, the actual malfunction location may be different from that displayed on CONSULT-II.