Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
COMPONENT INSPECTION Ambient SensorAfter disconnecting ambient sensor connector E34, measure resistance between terminals 1 (Y) and 2 (W) at sensor side, using the table.
If NG, replace ambient sensor.