Do you have access to Mitchell1 Prodemand If you are willing to share user/password (we can pay $250), please get in contact with us ASAP: email operation-charm [[at]] tuta.io or click to submit anonymously
Removal and Installation
Removal and Installation of Liquid TankREMOVAL
1. Remove condenser. Refer to "Removal and Installation of Condenser".
2. Clean liquid tank and its surrounding area, and remove dust and rust from liquid tank.
CAUTION: Be sure to clean carefully.
3. Remove mounting bolts from liquid tank.
4. Lift liquid tank bracket upward. Remove liquid tank bracket from protruding part of condenser.
5. Slide liquid tank upward, and then remove liquid tank.
INSTALLATION
Install liquid tank, and then install liquid tank bracket on condenser.
CAUTION:
- Make sure liquid tank bracket is securely installed at protrusion of condenser. (Make sure liquid tank bracket does not move to a position below center of liquid tank.)
- Replace O-rings of liquid tank pipe (inside pipe and outside pipe) with new ones, and then apply compressor oil to it when installing it.
- When recharging refrigerant, check for leaks.