Input and Output Revolution Sensor
Input and Output Revolution Sensor Inspection 1.
Disconnect the input and output revolution sensor connector.
2.
Use an ohmmeter to measure the resistance between terminals 1 and 2.
Standard resistance
Input revolution sensor:
387 - 473 Ohms (at 20°C, 4x2), 560 - 680 Ohms (at 20°C, 4x4) Output revolution sensor:
560 - 680 Ohms (at 20°C)