Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Vehicle Damage Warnings



CHARGING IN SERVICE BATTERIES

CHARGING EQUIPMENT MUST BE USED IN THE FOLLOWING MANNER







1. Do not boost charge the battery.
2. Do not charge at more than 16 volts.
3. Do not charge at more than 40 amps.
4. Do not during charging let the battery exceed a temperature of 50 degrees C.
5. Do not charge more than one battery per charger.
6. Do not leave a battery in a discharged condition but promptly re-charge.
7. Use chargers with the following specification:
- Automatic controls, no manual boost charge.
- Automatic switch off at charge termination.
(The use of such chargers will minimise potential battery damage caused by over charging).
8. Always check the electrolyte levels before and after charging, top up with distilled water if necessary.
9. After charging is complete carry out a post charge test and carry out the recommended actions accordingly.