Test 11
Module To Pick-up Coil Wiring Harness Connections:
1. Disconnect module 4 wire connector. Inspect connectors for dirt and corrosion.
2. Using a suitable ohmmeter, connect one lead to ground at distributor base. Using other lead, alternately measure resistance of harness wiring which connects to orange and violet wires of module connector and ground.
3. If test results are greater than 70,000 ohms, circuits are satisfactory. Refer to TEST 12. If test results are less than 70,000 ohms, inspect and repair as necessary wiring harness between module connector and distributor. Also inspect distributor grommet.