Recirculation Air Door Replacement
Reciculation Air Door Replacement
REMOVAL
A recirculation air door and vacuum actuator are used only on models with the optional air conditioning system.
1. Remove and disassemble the heater-A/C housing. Refer to: Heating and Air Conditioning, Housing Assembly HVAC, Service and Repair, Service and Repair
2. Remove the recirculation air door vacuum actuator from the lower heater-A/C housing.
Recirculation Air Door:
3. Reach inside the lower half of the heater-A/C housing and lift
4. Guide the recirculation air door lever through the air intake grille of the heater-A/C housing while removing the door from the housing.