Fluid Temperature Sensor Checking
FLUID TEMPERATURE SENSOR CHECKING 1.
Remove the fluid temperature sensor.
2.
Check the resistance between the connector terminal No.1 and 2 at the fluid temperature sensor side.
STANDARD VALUE 3.
If the resistance deviates from the standard value, then replace the temperature sensor.