Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Refrigerant Pressure Sensor / Switch: Testing and Inspection

A/C PRESSURE TRANSDUCER

INSPECTION




1. Measure the pressure of high pressure line by measuring voltage output between No. 1 and No. 2 terminals.
2. Inspect the voltage value whether it is sufficient to be regular value or not.

Voltage = Vdd * (0.025 * P + 0.1) [Kgf/sq.cm]
Voltage = Vdd * (0.254929 * P + 0.1) [Mpa]
Voltage = Vdd * (0.001758 * P + 0.074162 [PSIA]

3. If the measured voltage value is not specification, replace the A/C pressure transducer.