Center Registers
Center Registers
Removal
1
CAUTION: Care must be taken to avoid damage to the internal components of the center registers.
Release the center registers.
- Carefully release the 4 internal clips, apply an even outward pressure until the last clip is released.
2 Remove the center registers.
- Disconnect the 4 electrical connectors.
- Release the temperature blend door control cable.
3
NOTE:
Do not disassemble further if the component is removed for access only.
Remove the hazard flasher switch.
Installation
1 Install the hazard flasher switch.
2 Install the center registers.
- Attach the temperature blend door control cable.
- Connect the 4 electrical connectors.
- Position and secure the clips.