Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection




Wiring Diagram:





1. Remove front radiator grille.
2 Disconnect ambient temperature sensor connector.
3. Check resistance between terminals 1 and 2 of ambient temperature sensor connector at each temperature.

RESISTANCE:

At 25°C (77°F) 1.6 - 1.8 K Ohms
At 50°C (122°F) .05 - .07 K Ohms


HINT: As the temperature increases, the resistance decreases.

4. If the sensor fails this test replace the room temperature sensor.