Power Window

P15 POWER WINDOW MASTER SW
1 - GROUND : Always approx. 12 volts
3 - GROUND : Approx. 12 volts with ignition SW at ON or ST position Approx. 12 volts with key off power window operation
9 - GROUND : Always continuity
20 - GROUND : Continuity with power window master SW at MANUAL UP position Continuity with power window master SW at AUTO UP position
8 - GROUND : Continuity with power window master SW at MANUAL DOWN position Continuity with power window master SW at AUTO DOWN position

P12 POWER WINDOW CONTROL SW FRONT RH
7 - GROUND : Always approx. 12 volts
9, 12 - GROUND : Always continuity
1 - GROUND : Continuity with power window control SW at MANUAL UP position
: Continuity with power window control SW at AUTO UP position
6 - GROUND : Continuity with power window control SW at MANUAL DOWN position
: Continuity with power window control SW at AUTO DOWN position

P13 POWER WINDOW CONTROL SW REAR LH
7 - GROUND : Always approx. 12 volts
10, 12 - GROUND : Always continuity
1 - GROUND : Continuity with power window control SW at MANUAL UP position
: Continuity with power window control SW at AUTO UP position
6 - GROUND : Continuity with power window control SW at MANUAL DOWN position
: Continuity with power window control SW at AUTO DOWN position

P14 POWER WINDOW CONTROL SW REAR RH
7 - GROUND : Always approx. 12 volts
12 - GROUND : Always continuity
1 - GROUND : Continuity with power window control SW at MANUAL UP position
: Continuity with power window control SW at AUTO UP position
6 - GROUND : Continuity with power window control SW at MANUAL DOWN position
: Continuity with power window control SW at AUTO DOWN position

Power Rear Quarter Window

P6 POWER QUARTER WINDOW SW LH
4 - GROUND : Approx. 12 volts with ignition SW at ON or ST position
6 - GROUND : Always continuity

P7 POWER QUARTER WINDOW SW RH
4 - GROUND : Approx. 12 volts with ignition SW at ON or ST position
6 - GROUND : Always continuity