Air Conditioning Switch: Testing and Inspection

Condenser Fan And Front Air Conditioning

A5 A/C TRIPLE PRESSURE SW (A/C DUAL AND SINGLE PRESSURE SW)
1 - 4 : Open with the refrigerant pressure at less than approx. 2.0 kg/Sq.cm (196.1 kPa, 28.4 psi) or more than approx. 32.0 kg/Sq.cm (3136.1 kPa, 455 psi)
2 - 3 : Open below approx. 12.5 kg/Sq.cm (1225 kPa, 178 psi)
: Closed above approx. 15.5 kg/Sq.cm (1520 kPa, 220 psi)